Equipment financing
Financing is subject to application and credit approval.
Apply with TimePayment (opens in a new tab)Product information
Turbo Air TTE064BENM is a commercial walk-in cooler evaporator configured for professional walk-in refrigeration systems. Its published model-specific capacity, electrical requirements, and refrigerant information help contractors and facility teams evaluate system compatibility before ordering.
Crafted with blue hydrophobic-coated fins, the Turbo Air TTE064BENM evaporator unit cooler discourages water from remaining on the coil surface to resist corrosion. The inner-groove copper tubing improves internal refrigerant contact for effective heat transfer, and an air pass guard delivers full-coverage airflow. Driven by R448A refrigerant, the system incorporates a thermostatic expansion valve to control flow into the evaporator.
Turbo Air TTE064BENM is a commercial walk-in cooler evaporator. Use the exact model number when comparing replacement equipment, project schedules, service documents or refrigeration equipment lists.
Do not select a replacement by appearance or model family alone. Confirm the complete model number, refrigerant, voltage and phase, application temperature, design load, dimensions and paired condensing unit. A qualified refrigeration professional should verify the final selection.
Sometimes, but the replacement must be compatible with the complete refrigeration system. Confirm refrigerant, capacity, electrical requirements, controls and the paired condensing unit before ordering.
Have a qualified refrigeration professional evaluate design temperature, ambient conditions, insulation, product load, door openings, heat load, refrigerant, line-set requirements and paired equipment.
Review Product details for the published product information, and confirm the specifications of your selected configuration before ordering.
| Model | TTE064BENM |
|---|---|
| Manufacturer | Turbo Air |
| Type | Thin profile unit cooler |
| Defrost | Electric defrost |
| Capacity, R-404A (-20°F SST, 10°F TD) | 6,570 BTUH |
| Capacity, R-448A/R-449A (-20°F SST, 10°F TD) | 6,457 BTUH |
| Airflow | 1,487 CFM |
| Fans | 2 |
| Electrical | 208-230V / 1 ph / 60 Hz |
| Fan motor | EC motor, 1/25 HP, 0.90 total amps, 50 W |
| Defrost heaters | 1,110 W, 4.8 A at 230/1/60 |
| Coil inlet | 1/2 OD |
| Suction | 5/8 ID |
| Equalizer | 1/4 OD |
| Drain | 3/4 MPT |
| Valve package | R-448A/R-449A TXV and solenoid valve, factory mounted |
| Approx. net weight | 45 lb |
| Brand / vendor | Turbo Air |
|---|---|
| Equipment type | Walk-In Cooler Evaporator |
| Model | TTE064BENM |
| SKU | TTE064BENM |
| Width (overall length, dim. A) | 49.7 in |
|---|---|
| Depth | 19 in |
| Height | 9-3/8 in |
| Approx. net weight | 45 lb |
Contact our team with the product name and the specification or option you want to confirm.
Include the product, quantity, required configuration and delivery location in your quote request.
Open Shipping & support for the published freight, returns and custom-order policy links.
Product-specific documents and planning links remain in Product details when a separate resources section is not available.
Review the published policies and confirm product-specific requirements before placing your order.
Purchase through the product options above, or use one of these support paths for a financed or institutionally quoted order.
Financing is subject to application and credit approval.
Apply with TimePayment (opens in a new tab)Request documented pricing, freight planning, and configuration support before issuing a purchase order.
Request a formal quoteEstimates are for qualified buyers with approved credit (WAC) and reflect the equipment price only. Shipping, freight, and applicable taxes are not included and will increase your total and payments. Final amounts are set at checkout or on your quote.
Government and institutional buyers: request a PO quote.
Third-party programs, ratings and eligibility can change. Select a profile to verify its current details.
Efficiency & incentive planning
Programs vary by equipment class, exact model, installation address, electric utility and project timing. Use these official resources to verify eligibility before purchase—rebates are not guaranteed and should not be deducted from the equipment price unless your program administrator approves the project.
Current ENERGY STAR commercial refrigerator/freezer eligibility excludes walk-in coolers and freezers and remote condensing equipment. Do not assume a refrigeration system is ENERGY STAR certified unless the exact model appears in the applicable official product list.
Review ENERGY STAR eligibilityThe U.S. Department of Energy maintains the federal standards and test-procedure resources for covered walk-in cooler and freezer components. Application and compliance depend on the product and intended use.
View DOE walk-in guidanceState, local and utility incentives can change throughout the year. Search DSIRE by location, then confirm the model, project address, installer requirements and pre-approval deadline with the program administrator.
Search DSIRE incentivesSend us the installation ZIP code, utility provider and selected system. We can help you organize the equipment information your rebate administrator or contractor may request.
Not by default. The current ENERGY STAR commercial refrigerator/freezer criteria exclude walk-in coolers and freezers and remote condensing equipment. Certification should only be claimed when an exact model is listed by the applicable official program.
Possibly. Availability depends on the installation location, serving utility, equipment category, model specifications, contractor documentation and program dates. Check DSIRE and your utility before ordering, because some programs require pre-approval.
Official references: U.S. EPA ENERGY STAR, U.S. Department of Energy and the Database of State Incentives for Renewables & Efficiency (DSIRE). Program rules and funding may change.