Entry-tier 3-cadaver upright cooler in a standard-width cabinet — left- or right-hinged door built to your preference at no charge, self-contained 115V refrigeration, built in Johnson City, Tennessee.
At a glance
-
3-body capacity — standard-width upright · 600 lbs per tier
-
Door hinge — Left, Right, or Either at no charge — tell us your preference in order notes at checkout or call 1-888-792-9315
-
Modular insulated cabinet, 4″ urethane core
-
Self-contained refrigeration — 115V single-phase, NEMA 5-20R receptacle requirement
-
NSF, UL, ASTM E84 certified
-
Limited 15-year structural panel warranty · made in the USA
Specifications
| Body capacity |
3 cadavers, standard-width upright |
| Door hinge |
Left, Right, or Either — no charge; specify in order notes at checkout or by phone |
| Cabinet construction |
Modular insulated, 4″ urethane core |
| Refrigeration |
Self-contained |
| Operating range |
34–40°F body holding |
| Required air clearance |
1″–1.5″ around entire cabinet · 16″ above compressor — see VC-1.1
|
| Weight per tier |
600 lbs maximum per storage position |
| Gross ship weight |
1,500 lbs (freight, liftgate delivery included) |
| Voltage |
115V / 1-phase / 60 Hz · 4.6 A · NEMA 5-20R receptacle requirement |
| Certifications |
NSF, UL, ASTM E84 Class A, DOE/EPA EISA 2007, Prop 65 |
| Warranty |
Limited 15-year panel structural — see Warranty Policy (WR-1.0)
|
| Country of origin |
United States — Johnson City, Tennessee
|
| Manufacturer |
American Mortuary Coolers |
Electrical & Compressor Specifications
Amperage
4.6 A
115V · 1-phase · 60 Hz
Plug Type
NEMA 5-20R
Cord & plug supplied
| Supply voltage |
115V / 1-phase / 60 Hz |
| Unit amps (running) |
4.6 A |
| Minimum circuit ampacity (MCA) |
15.0 A |
| Circuit and overcurrent protection | Confirm the selected refrigeration package nameplate and factory electrical schedule with the installer. Do not size the breaker from generic product copy. |
| Cord & plug |
Factory cord/plug supplied; confirm plug and receptacle designation |
| Compressor system capacity |
2,900 BTU/h @ 95°F ambient · 35°F box |
| Refrigerant |
R-290 (low-GWP hydrocarbon) |
| Defrost |
Air defrost |
| Evaporator fan motor |
2-speed EC · 250 CFM |
| Efficiency (AWEF) |
5.61 — meets DOE minimum |
| Refrigeration unit size |
20.75″ H × 28.56″ W × 29.75″ D · 115 lb package |
| Compressor service clearance |
16″ minimum above and around the condensing unit |
| Listing |
UL listed — US & Canada |
| Refrigeration platform |
Heatcraft Climate Control PRO³ — factory electrical spec sheet (PT0032MANAPNA)
|
Plug-and-play on a dedicated 115V / 20-amp circuit — no hard-wiring required. A stamped electrical schedule ships with every quote.
Required Air Clearance & Owner Maintenance — Policy VC-1.1
Standard on all AMC drop-in refrigeration systems. These are conditions of warranty coverage, not recommendations.
-
1″–1.5″ minimum air gap around the entire cabinet — all sides and rear, maintained permanently.
-
16″ minimum unobstructed clearance above and around the compressor / condensing unit for airflow, heat rejection, and service access.
- No shelving, cabinetry, soffits, dropped ceilings, boxed enclosures, adjacent equipment, or stored goods may encroach on either envelope.
Owner Maintenance Responsibility
The customer is responsible for ongoing maintenance of the compressor and refrigeration system, including annual professional service as needed — coil cleaning, drain-line clearing, gasket inspection, and verification of refrigerant charge and temperature performance. Routine maintenance, consumables, labor, and service calls are not warranty items.
Published exterior dimensions do not include required clearance — add it when planning your space. Full terms: Ventilation & Clearance Policy (VC-1.1) · Warranty Policy (WR-1.0)
Important — Read Before Startup: 2026 Packaged Refrigeration System
Due to the changing refrigerant models under new Freon regulations and updated guidelines, it is critical that you completely read all startup instructions before using your packaged refrigeration system. Please be sure you understand your startup settings and the proper overflow and humidity drainage ports, which require hose adapters.
Condensation Drain Requirement
All 2026 Heatcraft compressors require a drain hose attached to the drain port for condensation, to maximize energy efficiency. Connect the supplied drain line to the drain port before startup.
External Drain Connection
In high-humidity environments or during continuous heavy run-times, the unit may experience overflow. To prevent this, the indoor unit is equipped with a 3/4″ NPT external drain connection that can be routed to an external drain line or a field-supplied condensate pump.
Internal Re-Evaporation
Indoor PRO³ models include a hot-gas re-evaporation pan beneath the compressor, which uses hot refrigerant gas to evaporate condensation naturally during normal operation.
2026 and Forward — Heatcraft PRO³
2026 and later packaged Heatcraft PRO³ systems include many new features made possible by an extremely high-efficiency process. Reviewing the startup documentation ensures these systems perform as designed.
American Mortuary Coolers accepts no liability or responsibility for a customer's failure to properly start up the new AW2 fully packaged, plug-in refrigeration units. If you have specific questions regarding functions and operations, please reach out prior to ordering.
Full startup manuals and tech bulletins: Packaged Refrigeration Manuals & Startup Guide
Questions before you order? Call 1-888-792-9315 or email cool@mymortuarycooler.com.
Sizing, weight ratings & cot compatibility
The 3-Body Standard Upright is the entry tier at 3-body capacity, built for small-to-mid funeral homes, single-physician coroner offices, hospital outpatient morgues, and crematory holding rooms. For bariatric clearance at the same capacity, see the 3-Body Extra Wide or side-loading 3-Body Extra-Wide Side-Load. Step down to the 2-Body Standard Width. Step up to the 6-Body Dual-Door.
Weight per tier: rated at 600 lbs maximum per storage tier, covering the full standard-width case envelope including case weight, tray, and cot board. For recurring bariatric cases exceeding 500 lbs, see the 3 Body Extra Wide (rated 850 lbs per tier).
Cot and tray compatibility: Confirm the selected cot or tray envelope, clear door opening, threshold, rack obstructions and loading method with AMC before ordering. Product links identify companion equipment, not a guaranteed fit.
Sizing methodology: mortuary cooler buyer's guide · how to choose the right size.
State-by-state availability & shipping
Ships factory-direct from Johnson City, Tennessee to all 50 states — most orders within 2 business days. Gross ship weight 1,500 lbs; liftgate delivery included. Common delivery destinations and state-level guides:
Alabama · Arizona · Arkansas · California · Colorado · Florida · Georgia · Illinois · Indiana · Iowa · Kansas · Kentucky · Louisiana · Maryland · Michigan · Minnesota · Mississippi · Missouri · Nebraska · Nevada · New Jersey · New Mexico · New York · North Carolina · Ohio · Oklahoma · Oregon · Pennsylvania · South Carolina · Tennessee · Texas · Utah · Virginia · Washington · Wisconsin
Financing & planning guides
-
0% financing at checkout — Shop Pay Installments for qualified buyers
-
1% back on every Shop Pay purchase
-
Extended financing on orders over $5,000 — apply here
-
Section 179 in-year tax treatment — guidance here
Frequently asked questions
What is the weight limit per tier?
600 lbs maximum per storage tier. For cases over 500 lbs, see the 3 Body Extra Wide rated at 850 lbs per tier.
What is the gross ship weight?
1,500 lbs gross. Liftgate delivery is included. Freight ships from Johnson City, Tennessee via common carrier. Most destinations receive in 3–7 business days from shipment.
How much clearance does it need around it?
A minimum 1″ to 1.5″ air gap around the entire cabinet, plus 16″ of unobstructed clearance above the compressor. This is standard on all drop-in refrigeration systems and is a condition of warranty coverage — see the Ventilation & Clearance Policy (VC-1.1).
Who is responsible for maintaining the compressor?
The owner. The customer is responsible for ongoing maintenance of the compressor and refrigeration system, including annual professional service as needed. Routine maintenance, cleaning, consumables, and service labor are not warranty items.
What electrical supply does it need?
A dedicated 115V / 20-amp circuit. The unit draws 4.6 running amps and ships with a cord-and-plug connection; confirm the required receptacle — plug-and-play, no hard-wiring. See the Electrical & Compressor Specifications above.
Do I need a drain line?
In high-humidity or high-temperature environments, yes — attach a hose to the external drain connection and route to a drainage source. Full details on the packaged refrigeration manuals page.
How does this compare to the extra-wide 3-body coolers?
Standard width fits the standard case envelope. The extra-wide variants ship with bariatric cabinet clearance and an 850 lb per tier rating.
How do I pick door hinge?
Match the swing to your prep-room flow, then tell us your preference — Left, Right, or Either — in the order notes at checkout, or call 1-888-792-9315 after ordering. There is no charge for door handing. "Either" lets the factory ship the standard-default hinge if you don't have a fixed plumbing or workflow constraint.
What temperature does it maintain?
34–40°F body holding standard.
Can it be financed?
Yes. 0% Shop Pay Installments. Qualifies for extended financing.
Where is it made?
Johnson City, Tennessee. American Mortuary Coolers, family-owned since 2009, A+ Rated by the Better Business Bureau.
Direct procurement: 1-888-792-9315 · cool@mymortuarycooler.com · request catalog · dealer inquiries