AME 1036-2 Wall Mount Embalming Service Station Owner & Service Manual
Specifications and dimensions, wall mounting, plumbing and electrical rough-in, commissioning, operation, numbered parts diagram with AME part numbers, plumber and electrician detail pages, care, troubleshooting, state drain codes and service records. Scan the QR code on the cover to return to this page.
Download Owner & Service Manual
All manuals & forms
Product Overview
The Wall Mount Embalming Service Station (Model 1036-2) from American Mortuary Equipment is a space-saving, 304 stainless steel wall-hung sink and water-control station for funeral home preparation rooms, hospital pathology and morgue suites, autopsy rooms, medical examiner and forensic centers, and university anatomy labs. It comes equipped with a spray-hose system, hot and cold water control, a reverse-flow aspirator, and a waste disposer, with an optional emergency hand-held eyewash.
Features
- Heavy-duty 304 stainless steel for corrosion resistance
- Self-closing pre-rinse spray valve on a 10-ft flexible hose with its own wall control valve
- 0.75 HP, 120 V continuous-feed waste disposer under the 12 × 16 × 8 in. sink, controlled by a 20 A toggle switch
- Deluxe reverse-flow aspirator that helps prevent suction clogs
- Pressure-balance tempering mixing valve with lever handle; cold flows first
- Utility faucet with 12-in. swing spout on an elbow-handle wall valve
- Built-in 20 A GFCI duplex receptacle on the back panel
- Z-bar wall mounting, open stainless shelving, removable lower shelf and front and side access panels for plumbing
- Optional emergency eyewash attachment
Technical Specifications
| Specification |
Value |
| Height |
71" |
| Length |
30" |
| Depth |
24.5" |
| Sink basin |
12" × 16" × 8" |
| Material |
304 stainless steel |
| Power |
110V with GFCI-protected receptacle |
| Electrical circuits |
Two 120 V circuits: 20 A dedicated to the disposer switch; 20 A to the GFCI receptacle; 4 × 4 in. junction box in cabinet |
| Water supply |
Single point: hot 1/2 in. and cold 3/4 in. NPT inside the cabinet; 58 to 60 psi and 4 gpm minimum for the aspirator |
| Drain |
1-1/2 in. standard (AME1036-2) or 2 in. (AME1036-2-2D) from the disposer P-trap |
| Mounting |
Two-piece Z-bar bracket at 68-1/2 in. AFF plus six 3/8 in. lower anchors into wall blocking |
| Models |
AME1036-2 standard drain · AME1036-2-2D 2 in. drain · Option SE emergency shower and eyewash |
Installation, plumbing and electrical
The station hangs on a two-piece Z-bar bracket: the wall half fastens to continuous blocking at 68-1/2 in. above the finished floor and six 3/8 in. anchors secure the lower cabinet. Hot (1/2 in.) and cold (3/4 in.) supplies connect at a single point inside the cabinet; the disposer discharges through a P-trap to a 1-1/2 in. or 2 in. building drain. Two 120 V circuits terminate in a 4 × 4 in. junction box: a dedicated 20 A circuit for the disposer through the toggle switch and a 20 A circuit for the GFCI receptacle. The lowest shelf lifts out for plumbing access. Rough-in dimensions, mounting steps, commissioning checks and wiring are in the owner and service manual below.
Waste handling and disposal
Aspirator discharge and table rinse flow into the 12 × 16 × 8 in. sink and through the 0.75 HP continuous-feed disposer, so soft waste never reaches the trap. Run cold water before switching the disposer on and for 15 seconds after the sink clears; keep instruments, sutures, gauze, plastic, glass and large bone out of the disposer. The reverse-flow aspirator backflushes its clear 10-ft hose without disconnecting. Atmospheric vacuum breakers on the aspirator and spray valve protect the building supply; a 2 in. drain outlet is available for Pennsylvania, Maryland and New Jersey preparation rooms.
Frequently Asked Questions
Yes, it is manufactured by American Mortuary Equipment in the United States.
Is it wall-mounted or free-standing? Wall-mounted only, optimized for compact spaces.
Is the spray hose removable? It features a 10-ft flexible hose with an ergonomic spray nozzle.
Does it include an aspirator? Yes, a built-in deluxe reverse-flow aspirator.
Can it be customized to our plumbing setup? Yes, the open, accessible back supports custom plumbing configurations.
What is the power requirement? Standard 110V with a GFCI-protected receptacle.
Is the eyewash attachment included? It is optional and can be added on request.
Is it suitable for a morgue, autopsy suite or forensic center? Yes. The 304 stainless construction, reverse-flow aspirator, GFCI receptacle and disposer serve hospital pathology and morgue suites, medical examiner and forensic facilities and anatomy labs as well as funeral home preparation rooms.
Are replacement parts available? Yes. Every serviceable part has an AME part number and its own quote-only page; see the replacement parts section below.
2″ drain upgrade for state code
Some states set the drain size for the preparation room. Pennsylvania requires a sink drain with 2-inch capacity (49 Pa. Code §13.174) and Maryland requires a drain pipe of at least 2 inches (COMAR 10.29.03.05). Choose 2″ Drain Upgrade above and the station is built with a 2″ drain outlet so your plumber can connect without reducers. Confirm current rules with your state board and plumbing inspector before you order.
Drain size and local code: we build it to comply
Pennsylvania, Maryland and New Jersey require a 2″ drain in the funeral preparation room, and many cities and counties add their own plumbing rules on top of the state code. We build every plumbing item to the requirement that applies to your room, including 2″ drain outlets, backflow protection and other code items. Select the 2″ Drain Upgrade option on this page, and add anything else in your order notes.
| State | Rule | Requirement |
|---|
| Pennsylvania | 49 Pa. Code §13.174 | Preparation-room sink with a 2″ capacity drain pipe; non-backflow aspirator or non-backflow valve |
| Maryland | COMAR 10.29.03.05 | Drain pipe at least 2″ in diameter; floor drainage in new, renovated or newly owned preparation rooms |
| New Jersey | N.J.A.C. 13:36-5.6 | Waste sink with a 2″ minimum drain; hydro-aspirator with an approved vacuum breaker |
| Massachusetts | 239 CMR 3.07 | Flush-rim sink, floor drain and a reduced-pressure or air-gap backflow device at the meter or property line |
How to get a code-compliant build
- Ask your plumbing inspector or state board for the required drain size, backflow device and any special fixture rule.
- At checkout, type the drain size, your city and county, and any special drain or code requirement in the Order notes box. On a PO or RFQ, put the same details in the notes.
- We confirm the build in writing before it ships. Questions: 1-888-792-9315 or po@mymortuarycooler.com.
State rules change. Confirm the current requirement with your inspector before you order. Request a quote · Send a PO
Replacement parts for the Wall Mount Embalming Service Station
Every serviceable part on the 1036-2 station has an AME part number. Match the installed part to the numbered diagram, then open the part page for the detail photo, connection sizes and plumber or electrician notes.

| Item | AME part no. | Description |
|---|
| 1 | AME-WSS-SPRAY | Pre-rinse spray valve assembly; head, handle, wall valve |
| 2 | AME-WSS-SPRAY-HOSE10 | Flexible spray hose, 10 ft |
| 3 | AME-WSS-GFCI | GFCI duplex receptacle, 20 A, with stainless plate |
| 4 | AME-WSS-SW | Disposer toggle switch, 20 A, with plate |
| 5 | AME-WSS-ASP | Deluxe hydro-aspirator with wall swivel valve; venturi, service kit |
| 6 | AME-WSS-HOSE-ASP10 | Clear aspirator hose, 10 ft |
| 7 | AME-WSS-MIX | Pressure-balance mixing valve; cartridge, seats and springs, trim |
| 8 | AME-WSS-FAUCET | Utility faucet with 12 in. swing spout; spout only |
| 9 | AME-WSS-DISP | Waste disposer, 3/4 HP, 120 V; sink flange and mounting assembly |
| 10 | AME-WSS-ZBAR | Z-bar wall mounting bracket set |
| 11 | AME-WSS-CONDUIT | Disposer liquid-tight conduit whip |
All AME replacement parts are quote only: open the part page and use Add to Quote, or call 1-888-792-9315 with the model, serial number and part number. Parts carry a one-year warranty with proper use (replacement parts only, no labor); parts sales are final.
Shop the complete Embalming Service Station parts family · Owner and service manual with removal and refit steps (PDF)