The Inspection Checklist — Quarterly (Compressor Annually)
1. Door seals & gaskets: inspect for cracks, tears, hardening, or brittleness; keep gaskets clean and debris-free; test the seal by closing the door on a dollar bill — you should feel resistance; replace damaged or worn gaskets — proper seals ensure temperature stability and energy efficiency. 2. Door handles & hardware: inspect and tighten handles, hinges, and latches; handles must operate smoothly and latch securely; check for loose hardware or wear; lubricate hinges and latches as recommended. 3. Casters & brakes: inspect wheels for cracks, chips, flat spots, or debris; confirm smooth roll; inspect brake engagement and release; tighten mounting bolts. Casters and racking are warranted 5 years from purchase. 4. Interior shelving (on rails): inspect for cleanliness, corrosion, or damage; shelves must slide smoothly on rails; check rails for alignment, damage, or debris; tighten rail hardware and shelf stops. Shelving and rails — 5 years. 5. Roller rack inserts: fully inspect for smooth operation; check rollers for wear, damage, or corrosion; confirm rack stops and guides function; clean and lubricate moving parts. Roller rack inserts — 5 years. 6. Compressor — annual inspection: fully inspect at least once annually; check for unusual noise, vibration, or excessive heat; inspect electrical connections for tightness; confirm the compressor is securely mounted. Compressor part is warranted 5 years from the installation date (part only, no labor); labor and other parts are covered 90 days from installation. Annual compressor maintenance is the customer’s responsibility. See RW-1.0. 7. Compressor drain: inspect the drain port and attached hose; hose must be clear, securely attached, and draining properly; flush the drain line if needed; verify no kinks or blockages — proper drainage prevents water buildup and system issues. 8. Interior components: inspect all interior gaskets, corners, and seams; check interior light function; inspect the evaporator coil area for frost buildup or debris; confirm fans are operational and unobstructed. 9. Temperature & performance: verify temperature accuracy with a calibrated thermometer; ensure the set point is appropriate and stable; check door operation and seal after temperature stabilizes; review the alarm system (if equipped) — consistent temperatures protect decedents and reduce risk. 10. Cleaning & sanitation: clean and disinfect interior and exterior surfaces; use approved stainless cleaners and disinfectants; avoid harsh chemicals that damage finishes or gaskets; wipe door seals, handles, and touch points. 11. Electrical & alarms: inspect the power cord and plug for damage; the outlet must be dedicated and properly grounded; test the alarm system, battery backup (if equipped), and notifications; replace batteries as needed — reliable alarms and power protect your facility and compliance.
Environmental Guidelines
Never store an upright cooler in a garage or walk-in cooler environment. Maintain clearance around ventilation openings, keep the cooler on a level, stable surface, and keep the room clean, dry, and well-ventilated — the proper environment protects your investment and ensures reliability.
⛔ REMOVE FROM SERVICE — MANDATORY
Remove the cooler from service immediately if any of the following are present: temperature out of range and not recovering • door seals damaged or not sealing • compressor failure or refrigerant leak • electrical faults or sparking • structural damage or instability • excessive frost or moisture buildup • unsafe or unsanitary conditions. Do not return to service until repairs are completed and verified safe by qualified personnel.
The purchasing facility is solely responsible for inspection, removal from service, and operator safety; continued use of damaged or failed equipment constitutes misuse at the facility's own risk, voids applicable warranty coverage under WR-1.0, and falls under the assumption-of-risk terms of our Product Liability, Assumption of Risk & Release and the stop-use conditions in TP-1.0. Refrigerant work requires EPA §608-certified technicians — see SY-1.0.
⭕ WARRANTY COMPLIANCE — PARTS ONLY. NO LABOR UNLESS SPECIFIED.
Compressor: 1 year from date of purchase (manufacturer parts only). Caster wheels & racking: 5 years from date of purchase (parts only). Structure (cooler cabinet): 10 years limited from date of purchase under normal conditions (parts only).
All warranties are parts only — no labor unless otherwise specified in writing by American Mortuary Coolers; any labor services are provided exclusively at AMC's discretion. You must perform quarterly safety and required checks for the warranty period (compressor: full inspection at least annually). Full, dated, fully verified inspection records — signed by the authorized person conducting each check, with facility name, model/serial, and date in service — must be maintained and produced for any warranty claim. Failure to perform required maintenance or maintain records voids warranty coverage. Full terms: Warranty Policy (WR-1.0).
Part of the Mortuary Cooler Maintenance Center series — mymortuarycooler.com/maintenance. Related: Shop upright mortuary coolers • Upright Pro Tips 2026 • Current seasonal bulletin • Official manuals & startup guides • Rack & rail maintenance • Standards Center™. B2B professional use only; buyer is responsible for OSHA, state OSHA, funeral-board, health-department, local code, employee training, safe operation, installation, maintenance, and all applicable regulatory compliance. Always reference the latest manufacturer manuals and startup documentation.
Need service, parts, or have questions about your upright cooler?
Model and serial ready — we'll walk the checklist, diagnose the issue, and ship the part.
Call 1-888-792-9315 or email cool@mymortuarycooler.com
American Mortuary Coolers • Built for Life's Critical Work • Johnson City, TN
Shop Upright Mortuary Coolers
Compare the actual equipment below, choose the required options and add an eligible configuration to your cart. Quote-only and configured systems retain their dedicated product path.
- Choose the equipment
- Select options and quantity
- Review your cart or itemized quote

THE USA
2-Body Mortuary Refrigerator Shell
PO accepted

THE USA
2-Body Extra-Wide Mortuary Refrigerator
PO accepted

THE USA
3-Body Extra-Wide Mortuary Refrigerator
PO accepted

THE USA
3-Body Mortuary Refrigerator
PO accepted
Compare cold storage around the space and loading plan
Start with the equipment you need to move into storage, the usable room dimensions and the available access route. An upright refrigerator, a roll-in cooler and a walk-in system are different configurations; compare their actual listings before choosing.
- Capacity and access: confirm the listed storage arrangement and loading direction.
- Fit: compare exterior and usable dimensions, door clearance and the delivery route.
- Configuration: identify refrigeration, floor, rack and tray selections separately.
- Project scope: confirm utilities, delivery requirements and the applicable written warranty.
Plan a phased mortuary-cooler replacement
Start with an inventory of the equipment in service, its dimensions and the workflow that must stay available during replacement. Identify the units needed first, the interfaces that must remain compatible and the later phases you want to budget. Separate a planning quantity from an approved purchase.
- For each phase, identify the model or specification, quantity, delivery location and intended purchasing period.
- Record dependencies such as door clearances, loading direction, transfer height, tray size, floor conditions and utilities where relevant.
- Request separate line items for equipment and selected accessories so the order can be reviewed by location and fiscal period.
- Review quote validity, current availability and delivery requirements before approving each phase; a planning quote is not a promise of a fixed future price.
Request a phased equipment or multi-location quote with the first purchase and later requirements clearly identified. Use the same approach for an independent facility, a public department or a corporate equipment-replacement program.
For several products or locations, request an itemized Upright Mortuary Coolers quote with selected models, quantities and delivery ZIP codes. Use general customer support for selection questions, and review the written warranty terms before ordering.
Plan year-end equipment purchases around the actual equipment and timing
Review current catalog prices, choose the required configuration and separate the first purchase from later replacement phases. Build an itemized priced quote, or request a formal equipment quote with quantities, locations and your purchasing period. Request written price validity rather than assuming an unannounced future price increase or an additional sale discount.
Can Section 179 affect an equipment purchase?
For tax years beginning in 2026, IRS Revenue Procedure 2025-32 sets a maximum Section 179 expense deduction of $2,560,000, reduced when qualifying property placed in service exceeds $4,090,000. These are statutory limits, not a promise that this purchase or every buyer qualifies.
The IRS explains that property is generally placed in service when ready and available for its specific use. Eligibility, business use, taxable income and other requirements matter; ordering, financing or paying before year-end does not by itself establish a deduction. Confirm treatment and timing with your tax professional before relying on a tax benefit.
Use our 2026 Section 179 planning guide and illustrative calculator alongside the selected model's requirements. Confirm freight, installation responsibilities and availability separately; a year-end planning request is not a delivery guarantee.
Compare your options. Choose your next step.
One source for funeral supplies and mortuary equipment, with nationwide shipping. Review the Upright Mortuary Coolers selection, compare product specifications and current pricing, then order the configuration you need or request an itemized quote.
- Choose the modelCompare the details against the work you need to do.
- Set your quantitiesReview the selected options and equipment subtotal.
- Buy or request a quoteReview freight, tax and available payment terms separately.
Need several items or delivery to more than one location? Include the models, quantities and delivery ZIP codes in your request. For general questions, contact customer support.